3Mixtatin versus MTA in pulp therapy of primary teeth: a systematic review and meta-analysis of current randomized
Mobina Sadat Zarabadi1, Parsa Firoozi2, Samira Basir Shabestari3
1Department of Pediatric Dentistry, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran.
Aim:
3Mixtatin (a combination of Metronidazole, Minocycline, and Ciprofloxacin along with statins) is a novel biomaterial in pulp therapy, while Mineral Trioxide Aggregate (MTA) is considered the gold standard in endodontics. This study aimed to compare the clinical and radiographic success rates of MTA and 3Mixtatin in pulp therapy of primary teeth.
Methods And Materials:
MEDLINE (PubMed), CENTRAL, Web of Science, Scopus, ProQuest databases, and Google Scholar were searched to identify randomized controlled trials (RCTs) on pulp therapy with 3Mixtatin and MTA in primary teeth, published up to February 2023. It should be noted that the protocol was previously registered in the International Prospective Register of Systematic Reviews (PROSPERO; CRD42021243626). RCTs were assessed independently by two researchers in terms of eligibility and quality. Data extracted and tabulated. The Cochrane Risk of Bias (RoB-2) tool was used to assess the risk of bias. The effect sizes were evaluated utilizing risk ratios (RRs). The heterogeneity investigation was conducted utilizing I² measurement at α = 0.10.
Results:
Out of 86 retrieval records, four articles met the inclusion criteria. Based on clinical and radiographic outcomes, the application of 3Mixtatin in the pulp therapy of primary teeth was as successful as MTA in 12 months (Clinical RR = 1.087 | Radiographic RR = 2.132). The RoB-2 tool showed a low risk of bias in all included RCTs.
Conclusion:
The limited evidence showed the clinical and radiographic efficacy of 3Mixtatin as a potential alternative to MTA. Further empirical research with larger sample sizes and strict methodology will be essential to substantiate this assertion.
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Therapeutic Drug Monitoring: Drug Analysis Methods


