Related Experiment Video
Updated: Jul 1, 2025

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Inter- and intra-observer reliability and agreement of O2Pulse inflection during cardiopulmonary exercise testing: A
Thomas Nickolay1,2, Gordon McGregor3,4,5, Richard Powell3,4
1Hull York Medical School, University of Hull, Hull, United Kingdom.
Abstract:
Cardiopulmonary exercise testing (CPET) is the 'gold standard' method for evaluating functional capacity, with oxygen pulse (O2Pulse) inflections serving as a potential indicator of myocardial ischaemia. However, the reliability and agreement of identifying these inflections have not been thoroughly investigated. This study aimed to assess the inter- and intra-observer reliability and agreement of a subjective quantification method for identifying O2Pulse inflections during CPET, and to propose a more robust and objective novel algorithm as an alternative methodology. A retrospective analysis was conducted using baseline data from the HIIT or MISS UK trial. The O2Pulse curves were visually inspected by two independent examiners, and compared against an objective algorithm. Fleiss' Kappa was used to determine the reliability of agreement between the three groups of observations. The results showed almost perfect agreement between the algorithm and both examiners, with a Fleiss' Kappa statistic of 0.89. The algorithm also demonstrated excellent inter-rater reliability (ICC) when compared to both examiners (0.92-0.98). However, a significant level (P ≤0.05) of systematic bias was observed in Bland-Altman analysis for comparisons involving the novice examiner. In conclusion, this study provides evidence for the reliability of both subjective and novel objective methods for identifying inflections in O2Pulse during CPET. These findings suggest that further research into the clinical significance of O2Pulse inflections is warranted, and that the adoption of a novel objective means of quantification may be preferable to ensure equality of outcome for patients.
More Related Videos
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
09:33Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: