Related Experiment Video
Updated: Jul 1, 2025

Differential Imaging of Biological Structures with Doubly-resonant Coherent Anti-stokes Raman Scattering CARS
Published on: October 17, 2010
Measurement of Carbon Dioxide Isotopes with Air-Lasing-Based Coherent Raman Spectroscopy
Yuzhu Wu1,2, Ning Zhang2,3, Xu Lu2,3
1School of Microelectronics, Shanghai University, Shanghai 200444, China.
Abstract:
Isotope detection is crucial for geological research, medical diagnostics, industrial production, and environmental monitoring. Various spectroscopic techniques are continually emerging for isotopic identification and accurate measurement. Herein, coherent Raman scattering (CRS) spectroscopy is developed for the quantitative detection of carbon dioxide isotopes, in which the N2+ air lasing coherently created in the interaction region is used as the probe. Benefiting from the narrow spectral width of air lasing, the Raman peaks of 12CO2 and 13CO2 can be well discerned, although their spectra partially overlap. The overlapped signals were proven to be the result of the coherent superposition of individual Raman signals. Based on that fact, a deconvolution algorithm was designed to retrieve the concentration ratio of the two isotopes. The relative error of the measurement is less than 6%. The CRS technique based on air lasing offers a potential approach for the quantitative characterization of molecular isotopes, especially in application scenarios of remote sensing or in situ detection.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Carbon-13 (¹³C) NMR: Overview

