Related Experiment Video
Updated: Jul 1, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Gap patterns and radiographic follow-up of newer-generation cementless total knee arthroplasty designs
Abigail Frazer1, Jason B T Lim2, Matthew G Teeter2
1From the Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ont. (Frazer, Teeter, Howard, Vasarhelyi, Lanting); the Department of Orthopaedic Surgery, Singapore General Hospital, Singapore, Singapore (Lim) afrazer7@uwo.ca.
Background:
Interest in cementless total knee arthroplasty (TKA) has increased with advancement of biomaterials and implant design and associated improved longevity. We sought to evaluate the gap patterns and radiolucent zones radiographically for 2 newer-generation cementless TKA designs.
Methods:
We retrospectively reviewed our single-institution database between January 2017 and December 2019. We identified patients with a porous keeled tibia base-plate with 4-bullet cruciform spikes and peri-apatite coated femoral component (study group 1) and patients who received a cementless porous coated femoral component and rotating platform tibia baseplate with 4 peripheral porous coated pegs around a central cone (study group 2). We identified gap patterns at 6 weeks and at 1 year or more postoperatively on radiographs, noting indications for reoperation.
Results:
We identified 228 patients in study group 1 and 41 patients in study group 2. At 1-year follow-up, we found evidence of resolved femoral gaps in 52 (72.2%) of 72 patients in study group 1 and 10 (58.8%) of 17 patients in study group 2 (p = 0.124). We identified 27 (84.3%) of 32 patients in study group 1 and 7 (70.0%) of 10 patients in study group 2 with resolved tibia gaps (p = 0.313). After 1 year, there were significantly more Zone 3a femoral zonal radiolucent gaps (p = 0.001) and Zone 8 tibia zonal radiolucent gaps (p = 0.002) in study group 2 than in study group 1. There were 4 reoperations for study group 1 and 0 reoperations for study group 2.
Conclusion:
The modern cementless TKA systems have varied gap patterns in postoperative radiographs, which may be attributed to the implant design. Most radiolucent gaps resolve radiographically on follow-up.
More Related Videos
09:31Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve