Related Experiment Video
Updated: Jul 1, 2025

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Association between patent ductus arteriosus flow and home oxygen therapy in extremely preterm infants
Jana Termerova1, Ales A Kubena2, Karel Liska3
1Department of Gynecology, Obstetrics and Neonatology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic. jana.termerova@vfn.cz.
Background:
Central blood flow measurements include the estimation of right and left ventricular output (RVO, LVO), superior vena cava (SVC) flow, and calculated patent ductus arteriosus (PDA) flow. We aimed to provide an overview of the maturation patterns of these values and the relationship between PDA flow and the need for home oxygen therapy.
Methods:
This prospective single-center study was conducted in infants born at <26 weeks of gestation. We performed echocardiographic measurements five times during their life (from the 4th post-natal day to the 36th postmenstrual week).
Results:
Sixty patients with a mean birth weight of 680 (590, 760) g were included. Postnatal development of LVO and PDA flow peaked at the end of the second postnatal week (427 and 66 mL/kg/min, respectively). The RVO increased between days 4 and 7-8. The SVCF was most stable. The development curves of PDA flow differed between the groups with (n = 28; 47%) and without home oxygen therapy.
Conclusion:
We present the central blood flow values and their postnatal development in infants <26 weeks of gestation. This study demonstrates the association between PDA flow and the future need for home oxygen therapy.
Impact:
This study enriches our knowledge of the long-term development of central blood flow parameters and derived patent ductus arteriosus (PDA) flow in extremely preterm infants (<26 weeks). While pulmonary resistance decreased, PDA flow continued to increase from day 4 to the end of the second week of life. Similarly, left ventricular output increased as a marker of preload. The superior vena cava flow remained stable. The observed association between PDA flow and an unfavorable respiratory outcome is important for future studies focusing on the prevention of chronic lung disease.
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...