Related Experiment Video
Updated: Jul 1, 2025

A Model of Glaucoma Induced by Circumlimbal Suture in Rats and Mice
Published on: October 5, 2018
Case report: Management of recurrent pupillary optic capture with sutureless surgical technique using 7-0
Dong Hyeon Kim1, Da Ru Chi Moon2, Yong Koo Kang1
1Department of Ophthalmology, School of Medicine, Kyungpook National University, Kyungpook National University Hospital, Daegu, Republic of Korea.
Background:
To report a novel surgical technique for recurrent pupillary optic capture after flanged intraocular lens (IOL) fixation.
Methods:
In this retrospective case series, we detail our use of two parallel 7-0 polypropylene sutures passed between the iris plane and the optic of scleral-fixated IOL to address pupillary optic capture. Flanges were created using ophthalmic cautery to secure it to the sclera without suture.
Results:
Two eyes with pupillary optic capture underwent a sutureless surgical technique using 7-0 polypropylene flanges. No recurrences of pupillary optic capture were observed during the 1-year follow-up.
Conclusion:
Our sutureless surgical technique using a 7-0 polypropylene flange was an effective, efficient, and less invasive approach for treating recurrent pupillary optic capture.