Staphylococcus aureus small colony variants: A potentially underestimated microbiological challenge in peritoneal
Markus Obermueller1, Ludwig Traby1, Matthias Weiss-Tessbach2
1Department of Medicine I, Division of Infectious Diseases and Tropical Medicine, Medical University Vienna, Vienna, Austria.
Introduction:
Peritonitis remains the major infectious complication in the setting of peritoneal dialysis (PD). Despite known only moderate pathogenicity, the most frequently detected pathogens in PD-related peritonitis are surprisingly coagulase-negative staphylococci. However, this could be explained, at least in part, by Staphylococcus aureus small colony variants (SCVs) induced by PD fluids (PDFs) and misidentified by routinely used microbiological methods.
Material And Methods:
Bacteria were exposed to commonly used PDFs in various regimens designed to simulate daily use as closely as possible. Wild-type isolates and SCVs were subsequently used to determine minimum inhibitory concentrations (MICs), in vitro biofilm formation capacities, and auxotrophies. Underlying genetic alterations were investigated using whole-genome sequencing, and various microbial identification methods were tested to determine their performance for wild-types and SCVs.
Results:
Stable SCVs could be isolated most successfully after exposure to glucose-containing PDFs alone. The reading of MICs was significantly affected by the reduced growth of SCVs, resulting in lower MIC values in 44% of all tests. Nonsynonymous mutations were found in all but one SCV, while only two isolates showed typical auxotrophic responses. While MALDI-TOF, PCR and Pastorex Staph-Plus correctly identified all S. aureus SCVs, API-Staph and VITEK-2 yielded identification rates of only 40% and 10%, respectively.
Conclusions:
Overall, the present study has shown that commercially available PDFs induce S. aureus SCVs in vitro, which are difficult to identify and test for antimicrobial susceptibility and can potentially lead to recurrent or persistent infections. Thus, they represent a potentially underappreciated challenge not only for microbiologists, but also for clinicians.
Related Concept Videos
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Peritoneal Dialysis III: Nursing Management
Staphylococcal Skin Infections
Clinical Significance of Antibiotic Resistance