Related Experiment Video
Updated: Jul 1, 2025

Quantification of Heavy Metals and Other Inorganic Contaminants on the Productivity of Microalgae
Published on: July 10, 2015
Monitoring of Essential and Toxic Elements in Multivitamin/Mineral Effervescent Tablet Supplements and Safety
İrem Uslu1, Orkun Alp2, Bensu Karahalil3,4
1Department of Toxicology, Faculty of Pharmacy, Gazi University, Ankara, 06330, Turkey. irem.uslu@drogsan.com.tr.
Abstract:
Multivitamin/mineral (MVM) supplements are the most commonly utilized dietary supplements by many populations. However, there is a severe concern about their adverse effects due to elemental impurities. In the present study, it was aimed to determine the levels of 11 elemental impurities (Cd, Pb, As, Hg, Co, V, Ni, Se, Mo, Cu, and Cr) by inductively coupled plasma-mass spectrometry (ICP-MS) and evaluate the human health risk associated with the consumption of 33 MVM effervescent tablet supplements available in Turkey. The precision of the method in terms of relative standard deviation (RSD) was less than 4.6%. The accuracy of the method was tested with recovery experiments, and the results ranged between 86 and 107%. The impurity levels for Cd, Pb, As, Co, V, Ni, Se, Mo, Cu, and Cr were found between 0.011-0.050, 0.025-0.098, 0.018-0.056, 0.010-0.626, 0.027-0.290, 0.026-1.65, 1.92-21.83, 0.034-34.09, 0.140-183.9, and 0.033-13.10 µg/g, respectively, and Hg was not detected in any sample. The calculated concentrations for elemental impurities complied with EMA and USP guidelines, except one supplement for Se (21.83 µg/g) with a permitted limit of 15 µg/g. The hazard quotient (HQ) and hazard index (HI) levels were below 1 for all samples within the ranges of 3.4 × 10-1-1.4 × 10-6 for HQ and 7.8 × 10-1-1.4 × 10-6 for HI indicating that there is no risk for consumption. The carcinogenic risk (CR) of As was between 1.7 × 10-6 and 5.9 × 10-6, below the threshold value of 1 × 10-4. The results showed that there is no risk to human health.
More Related Videos
09:23Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015
04:53Author Spotlight: Advances in Evaluating Human Lung Epithelial Cells' Response to Metal-Organic Frameworks
Published on: May 26, 2023
Related Concept Videos
Minerals
Major...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
The Periodic Table and Organismal Elements
Drug Regulation