Related Experiment Video
Updated: Jul 1, 2025

The Use of a β-lactamase-based Conductimetric Biosensor Assay to Detect Biomolecular Interactions
Published on: February 1, 2018
Development of double-layer poly (amino acid) modified electrochemical sensor for sensitive and direct detection of
Yirong Ma1, Xinran Wei1, Jiameng Xu1
1Department of Pharmaceutical Analysis, School of Pharmacy, Xi'an Jiaotong University, Xi'an, 710061, China.
Abstract:
Screening for illegal use of glucocorticoids (GCs) in cosmetics by electrochemical methods is extremely challenging due to the poor electrochemical activity of GCs. In this study, poly-L-Serine/poly-Taurine modified electrode (P(Tau)/P(L-Ser)/GCE) was prepared for sensitive and direct determination of betamethasone in cosmetics by a simple two-step in situ electropolymerization reaction. The relevant parameters of preparation and electroanalytical conditions were respectively studied, including the concentration of polymerization solution, the number of scanning circles and the scanning rate. The SEM and EDS mapping demonstrated successful preparation of P(Tau)/P(L-Ser)/GCE. The electro-catalytic properties of the obtained electrodes were investigated using cyclic voltammetry and differential pulse voltammetry methods, showing a remarkable improvement of sensitivity for the detection of betamethasone due to the synergic effect of both P(L-Ser) and P(Tau). In addition, we investigated the electrochemical reduction of betamethasone on the surface of modified electrode. It was found that the process was controlled by diffusion effect and involved the transfer of two electrons and two protons. Then the electrochemical sensor method based on P(Tau)/P(L-Ser)/GCE was established and delivered a linear response to betamethasone concentration from 0.5 to 20 μg mL-1 with a limit of detection of 32.2 ng mL-1, with excellent recoveries (98.1%-106.8%) and relative standard deviations (<4.8%). Furthermore, the established electrochemical sensor method was compared with conventional HPLC method. The results showed that both of them were comparable. Moreover, the established electrochemical sensor method was with the merits of short analysis time, environmentally friendly, low cost and easy to achieve in-site detection.
More Related Videos
10:48Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
07:07Synthetic Methodology for Asymmetric Ferrocene Derived Bio-conjugate Systems via Solid Phase Resin-based Methodology
Published on: March 12, 2015