Related Experiment Video
Updated: Jul 1, 2025

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Statistical shape models that predict native glenoid width based on glenoid height are inaccurate in their current
Lukas P E Verweij1, Nobuyuki Yamamoto2, Atsushi Arino2
1Department of Orthopaedic Surgery, Tohoku University School of Medicine, Sendai, Japan; Department of Orthopedic Surgery and Sports Medicine, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Musculoskeletal Health Program, Amsterdam, the Netherlands; Amsterdam Shoulder and Elbow Centre of Expertise (ASECE), Amsterdam, the Netherlands.
Statistical shape models for glenoid width prediction show significant measurement errors, even with strong correlations. Relying on the contralateral shoulder is recommended to minimize errors in determining bone loss.
Area of Science:
- Orthopedics
- Radiology
- Biomedical Engineering
Background:
- Unclear measurement errors in statistical shape models for predicting native glenoid width.
- Need to assess accuracy of models using glenoid height for determining anterior glenoid bone loss.
Purpose of the Study:
- Create and validate a statistical shape model for glenoid width using 3D-CT measurements.
- Determine measurement errors of existing 3D-CT statistical shape models.
Main Methods:
- Retrospective cross-sectional study of patients with traumatic anterior shoulder dislocation.
- 3D segmentation and measurement of glenoid height and width from CT scans.
- Calculation of measurement error as percentage deviation from native glenoid width.
Main Results:
- Strong correlation (r=0.80) between glenoid height and native glenoid width.
- Developed model: native glenoid width = 0.75 × glenoid height - 0.61, with 5% ± 4% average error.
- Existing models showed higher errors: Giles et al. (10% ± 7%), Chen et al. (6% ± 5%), Rayes et al. (9% ± 6%).
Conclusions:
- Statistical shape models for estimating glenoid width based on height have unacceptable measurement errors.
- Caution is advised when using these models for glenoid bone loss assessment.
- Using the contralateral side as a reference is preferred to minimize morphologic differences and errors.