Automatic procedure for modelling, calibration, and optimization of a three-component chromatographic separation
Daniel Espinoza1, Simon Tallvod1, Niklas Andersson1
1Department of Chemical Engineering, Lund University, Lund, Sweden.
Abstract:
The current landscape of biopharmaceutical production necessitates an ever-growing set of tools to meet the demands for shorter development times and lower production costs. One path towards meeting these demands is the implementation of digital tools in the development stages. Mathematical modelling of process chromatography, one of the key unit operations in the biopharmaceutical downstream process, is one such tool. However, obtaining parameter values for such models is a time-consuming task that grows in complexity with the number of compounds in the mixture being purified. In this study, we tackle this issue by developing an automated model calibration procedure for purification of a multi-component mixture by linear gradient ion exchange chromatography. The procedure was implemented using the Orbit software (Lund University, Department of Chemical Engineering), which both generates a mathematical model structure and performs the experiments necessary to obtain data for model calibration. The procedure was extended to suggest operating points for the purification of one of the components in the mixture by means of multi-objective optimization using three different objectives. The procedure was tested on a three-component protein mixture and was able to generate a calibrated model capable of reproducing the experimental chromatograms to a satisfactory degree, using a total of six assays. An additional seventh experiment was performed to validate the model response under one of the suggested optimum conditions, respecting a 95 % purity requirement. All of the above was automated and set in motion by the push of a button. With these results, we have taken a step towards fully automating model calibration and thus accelerating digitalization in the development stages of new biopharmaceuticals.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...