Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Analysis of OCT Scanning Parameters in AMD and RVO
Claus von der Burchard1, Johann Roider1, Timo Kepp2
1Department of Ophthalmology, Kiel University, 24105 Kiel, Germany.
Abstract:
Optical coherence tomography (OCT) is an extensively used imaging tool for disease monitoring in both age-related macular degeneration (AMD) and retinal vein occlusion (RVO). However, there is limited literature on minimum requirements of OCT settings for reliable biomarker detection. This study systematically investigates both the influence of scan size and interscan distance (ISD) on disease activity detection. We analyzed 80 OCT volumes of AMD patients and 12 OCT volumes of RVO patients for the presence of subretinal fluid (SRF), intraretinal fluid (IRF), and pigment epithelium detachment (PED). All volume scans had a scan size of 6 × 6 mm and an ISD of 125 µm. We analyzed both general fluid distribution and how biomarker detection sensitivity decreases when reducing scan size or density. We found that in AMD patients, all fluids were nearly normally distributed, with most occurrences in the foveal center and concentric decrease towards the periphery. When reducing the scan size to 3 × 3 and 2 × 2 mm, disease activity detection was still high (0.98 and 0.96). Increasing ISD only slightly can already compromise biomarker detection sensitivity (0.9 for 250 µm ISD against 125 µm ISD).
More Related Videos
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
Related Concept Videos
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...