Employing the Forced Oscillation Technique for the Assessment of Respiratory Mechanics in Adults
Published on: February 9, 2022
Breath Measurement Method for Synchronized Reproduction of Biological Tones in an Augmented Reality Auscultation
Yukiko Kono1, Keiichiro Miura2, Hajime Kasai3,4
1Department of Medical Engineering, Graduate School of Science and Engineering, Chiba University, 1-33 Yayoicho, Inage-ku, Chiba-shi 263-8522, Chiba, Japan.
Abstract:
An educational augmented reality auscultation system (EARS) is proposed to enhance the reality of auscultation training using a simulated patient. The conventional EARS cannot accurately reproduce breath sounds according to the breathing of a simulated patient because the system instructs the breathing rhythm. In this study, we propose breath measurement methods that can be integrated into the chest piece of a stethoscope. We investigate methods using the thoracic variations and frequency characteristics of breath sounds. An accelerometer, a magnetic sensor, a gyro sensor, a pressure sensor, and a microphone were selected as the sensors. For measurement with the magnetic sensor, we proposed a method by detecting the breathing waveform in terms of changes in the magnetic field accompanying the surface deformation of the stethoscope based on thoracic variations using a magnet. During breath sound measurement, the frequency spectra of the breath sounds acquired by the built-in microphone were calculated. The breathing waveforms were obtained from the difference in characteristics between the breath sounds during exhalation and inhalation. The result showed the average value of the correlation coefficient with the reference value reached 0.45, indicating the effectiveness of this method as a breath measurement method. And the evaluations suggest more accurate breathing waveforms can be obtained by selecting the measurement method according to breathing method and measurement point.
Related Concept Videos
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.