Purpose:
To evaluate the effectiveness and safety of pre-emptive transcatheter arterial embolization (P-TAE) for aortic side branches (ASBs) to prevent Type 2 endoleaks (EL2) before endovascular aneurysm repair (EVAR) using the Excluder stent-graft system (Excluder).
Materials And Methods:
In this prospective, multicenter study, 80 patients (mean age, 79.1 years [SD ± 6.7]; 85.0% were men; mean aneurysmal sac diameter, 48.4 mm [SD ± 7.4]) meeting the eligibility criteria were prospectively enrolled from 9 hospitals. Before EVAR, P-TAE was performed to embolize the patent ASBs originating from the abdominal aortic aneurysm. Contrast-enhanced computed tomography (CT) was performed at 1 month and 6 months after EVAR. The primary endpoint was EL2 incidence at 6 months, and the secondary endpoints were aneurysmal sac diameter changes at 6 and 12 months, P-TAE outcomes, adverse events related to P-TAE, reintervention, and aneurysm-related mortality.
Results:
All patients successfully underwent P-TAE without serious. Coil embolization was successful in 81.6% of ASBs. EL2 incidence at 6 months was identified in 18 of 70 (25.7%) patients. Aneurysmal sac diameter shrinkage (≥5 mm) was observed in 30.0% of patients at 6 months and in 40.9% at 12 months. Only 1 patient required reintervention for EL2 within 1 year of EVAR; aneurysm-related deaths were not observed.
Conclusions:
P-TAE for ASBs before EVAR using Excluder is a safe and effective strategy. It aids in achieving early aneurysmal sac shrinkage and reduces EL2 reintervention at 1 year after EVAR.