Related Experiment Video
Updated: May 6, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Inter-Rater Reliability for the Amputation Endpoint in the National Vascular Quality Initiative
Kim G Smolderen1, Gaëlle Romain2, Lindsey Scierka2
1Vascular Medicine Outcomes Program, Department of Internal Medicine, Section of Cardiovascular Medicine, Yale University School of Medicine, New Haven, Connecticut, USA; Psychology Section, Department of Psychiatry, Yale University School of Medicine, New Haven, Connecticut, USA.
Background:
National quality reporting efforts after revascularization for peripheral artery disease (PAD) are ongoing. Validation of endpoints are necessary in national quality registries.
Objectives:
This study sought to examine the interrater reliability for the endpoint of major amputation at 1 year in the Vascular Quality Initiative (VQI) registry and the Medicare-linked Vascular Quality Initiative registry (VQI-VISION) against electronic health record (EHR) review.
Methods:
Surgical or endovascular revascularization procedures between January 1, 2010, and December 31, 2017, in the VQI registry and VQI-VISION for 2 academic health systems were queried. Major amputation data were abstracted by trained data collectors for the VQI and derived from Current Procedural Terminology codes for VQI-VISION. Cases underwent protocolized adjudication for the endpoint of major amputation by EHR review. Paired tests were used to evaluate the sensitivity and specificity. Spearman's ρ and Cohen's κ were used to evaluate interrater reliability.
Results:
Amputation endpoints for 1,936 revascularizations were examined. Compared with major amputation data in EHR review, the sensitivity for the VQI registry was 35.9% and the specificity was 99.4% (ρ = 0.53; κ = 0.48). For VQI-VISION, sensitivity was 67.7% and specificity was 98.9% (ρ = 0.75; κ = 0.74). For any amputation in VQI data, sensitivity was 35.3% and specificity was 99.3% (ρ = 0.53; κ = 0.46), and for VQI-VISION, they were 71.6% and 97.7%, respectively (ρ = 0.75; κ = 0.74).
Conclusions:
Almost two-thirds of the amputations in the VQI registry and one-third of amputations in VQI-VISION were missing at 1 year compared against adjudicated EHR review. In preparing for national reporting systems for major amputation tracking, data collection system reform is needed.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
08:16High-Resolution Three-Dimensional Imaging of the Footpad Vasculature in a Murine Hindlimb Gangrene Model
Published on: March 16, 2022
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Artery Disease III: Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management