Related Experiment Video
Updated: Jul 1, 2025

3D Printing of Preclinical X-ray Computed Tomographic Data Sets
Published on: March 22, 2013
Assessment of attenuation properties for SLA and SLS 3D-printing materials in X-ray imaging and nuclear medicine
Stefan Weber1, Andreas Block2, Felix Bärenfänger2
1TU Dortmund, August-Schmidt-Straße 1, Dortmund 44227, Germany.
Abstract:
In recent years, access to 3D printers has become increasingly affordable. Alongside industrial and private applications, the significance of 3D printing in the clinical context is also growing. For instance, 3D printing processes enable the production of individual anatomical models that can be used to support patient communication or aid in surgical planning. While filament 3D printing is common, stereolithography (SLA) and selective laser sintering (SLS) printing processes offer higher precision. For the use of 3D printing materials in radiology, understanding their attenuation properties concerning ionizing radiation is crucial. Polymethyl methacrylate (PMMA) serves as an important reference material for radiological applications in this regard. In this research, linear- and mass attenuation coefficients of 38 SLA-/SLS-materials from Formlabs (Somerville, Massachusetts, USA) and PMMA will be determined through intensity measurements in nuclear medicine for the radionuclides technetium-99 m and iodine-131, as well as for X-ray imaging in the range of 60 kVp - 110 kVp tube voltage. Based on the mass attenuation coefficients, correction factors in respect to PMMA will be calculated for each material. A significant number of materials exhibit a deviance within approximately ±5% in respect to PMMA regardless of radiation energy. However, certain materials from the dental and industrial application show deviances up to +500% at the lower end of radiation energy spectrum. In conclusion, most materials can be considered equivalent to PMMA with only minor adjustments required. Materials with high deviances can be utilized as high-contrast materials in custom X-ray phantoms.
More Related Videos
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
07:57Scaled Anatomical Model Creation of Biomedical Tomographic Imaging Data and Associated Labels for Subsequent Sub-surface Laser Engraving SSLE of Glass Crystals
Published on: April 25, 2017
Related Concept Videos
X-ray Imaging
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Radiological Investigation I: X-ray and CT