Related Experiment Video
Updated: Jul 1, 2025

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Limb Length Discrepancy After Intraosseous Line Malpositioning: A Case Report
Rebekah M Kleinsmith1, Heather Kowalski2
1Department of Orthopaedic Surgery, TRIA Orthopaedic Center, Bloomington, Minnesota.
Case:
We will present the case of a 6-year-old girl who presented with a 3-cm limb length discrepancy after intraosseous line placement at age 14 months without other known history of trauma or infection to account for the growth arrest. Imaging revealed a left proximal tibial physeal bar amenable to surgical resection with autologous lipotransfer. At 10 months postoperatively, physical examination and imaging demonstrated a stable 3-cm leg length discrepancy with an interval increase in the length of the left tibia in proportion to the growth of the right side with an increase in valgus alignment that will continue to be monitored and addressed as indicated.
Conclusion:
Pediatric intraosseous line placement presents unique challenges and can ultimately lead to physeal injury and growth arrest in the case of malpositioning.