Effective chloramine management without "burn" in biofilm affected nitrifying tanks using a low dose of copper
Dipok Chandra Sarker1, K C Bal Krishna2, Maneesha P Ginige3
1Department of Civil and Construction Engineering, Curtin University, GPO Box U1987, Perth, WA, 6845, Australia.
Abstract:
This paper highlights the potential to effectively inhibit nitrification and restore chloramine levels using a low copper concentration in a biofilm-affected (surface-to-volume ratio 16 m-1) continuous-flow laboratory-scale chloraminated system. High nitrite and low chloramine containing tanks are always recovered with chlorine "burn" by water utilities. The "burn" is not only costly and operationally complex, but also compromises the water quality, public health, and customer relations. A laboratory system comprising five reactors connected in series was operated. Each reactor simulated conditions typically encountered in full-scale systems. Low amount of copper (0.1-0.2 mg-Cu L-1) was dosed once per day into nitrified reactors. At any given time, only one reactor was dosed with copper. Not only inhibition of nitrification, chloramine decay associated with bulk water, biofilm and sediments also improved. However, the improvement was quicker and more significant when the influent to the reactor contained a high chloramine and a low nitrite concentration. Ammonia oxidising microbes exhibited resilience when exposed to low copper and chloramine concentrations for an extended period. Chloramine decay due to planktonic microbes and chemical reactions in bulk water decreased more rapidly than decay attributed to biofilm and sediments. The concept "biostable residual chlorine" explained how copper and chloramine can inhibit nitrification. Once nitrification was inhibited, the chloramine supplied from upstream effectively continued to suppress downstream nitrification, and this effect lasted more than 50 days even at 22 °C. The findings could be used to develop short-term copper dosing strategies and prevent negative impacts of nitrification and breakpoint chlorination.
More Related Videos
16:21Quantifying Fish Swimming Behavior in Response to Acute Exposure of Aqueous Copper Using Computer Assisted Video and Digital Image Analysis
Published on: February 26, 2016
09:43Protocol for Acute and Chronic Ecotoxicity Testing of the Turquoise Killifish Nothobranchius furzeri
Published on: April 24, 2018
Related Concept Videos
Metabolism of Chemolithotrophs
Microbial Leaching
Microbial Corrosion