Related Experiment Video
Updated: May 6, 2026

06:44
Development of a Novel Task-oriented Rehabilitation Program using a Bimanual Exoskeleton Robotic Hand
Published on: May 20, 2020
7.0K
A soft, synergy-based robotic glove for grasping assistance
Ryan Alicea1, Michele Xiloyannis2,3, Domenico Chiaradia4
1Assistive Robotics and Interactive ExoSuits (ARIES) Lab, Institute for Computer Engineering (ZITI), Heidelberg University, Heidelberg, Germany.
Wearable Technologies
|March 15, 2024
Summary
This robotic glove enhances hand function for spinal cord injury patients. A preliminary study showed a 50% improvement in a grasping test, aiding daily activities.
Area of Science:
- Robotics
- Rehabilitation Engineering
- Biomedical Engineering
Background:
- Spinal cord injury (SCI) often impairs hand function, limiting independence.
- Existing assistive devices can be cumbersome or lack versatility.
- Restoring grasp capability is crucial for activities of daily living (ADLs).
Purpose of the Study:
- To introduce a novel soft, tendon-driven robotic glove for grasp augmentation.
- To provide rehabilitation assistance for individuals with post-SCI.
- To evaluate the glove's effectiveness in improving hand function.
Main Methods:
- The glove utilizes an underactuation design and postural synergies for versatile grasping with a single actuator.
- Device efficiency and force output linearity were characterized for cylindrical and pinch grasps.
- A preliminary case study involved a participant with C7 incomplete SCI performing the Box and Block test.
Main Results:
- The lightweight and easy-to-don glove generated sufficient force for ADLs.
- Force output was linear in both cylindrical and pinch grasp configurations.
- The synergy-inspired actuation minimally altered natural force distribution across fingers.
- The participant demonstrated a 50% improvement in the Box and Block test (6 vs. 4 blocks).
Conclusions:
- The soft robotic glove effectively augments grasp capability and aids SCI rehabilitation.
- The underactuation and synergy-based design offers a promising approach for assistive devices.
- The glove shows potential for improving functional performance in SCI patients.
Related Concept Videos
Muscles of the Forearm that Move the Hand and Fingers
3.4K
The muscles of the forearm that move the wrist, hand, and digits are numerous and diverse. They can be classified into two groups based on their location and function — the anterior and posterior compartment muscles.
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
3.4K
Mechanical Systems
904
Mechanical systems are analogous to to electrical networks where springs and masses play similar roles to inductors and capacitors, respectively. A viscous damper in mechanical systems functions similarly to a resistor in electrical networks, dissipating energy. The forces acting on a mass in such systems include an applied force in the direction of motion, counteracted by forces from the spring, a viscous damper, and the mass's acceleration. This interplay of forces is mathematically...
904