Related Experiment Video
Updated: Jun 30, 2025

In Vivo Assessment of Alveolar Macrophage Efferocytosis Following Ozone Exposure
Published on: October 22, 2019
Ozone Generation from a Germicidal Ultraviolet Lamp with Peak Emission at 222 nm
Michael F Link1, Andrew Shore1, Behrang H Hamadani1
1National Institute of Standards and Technology, Gaithersburg, MD, 20899, USA.
None:
Recent interest in commercial devices containing germicidal ultraviolet lamps with a peak emission wavelength at 222 nm (GUV222) has focused on mitigating virus transmission indoors while posing minimum risk to human tissue. However, 222 nm light can produce ozone (O3) in air. O3 is an undesirable component of indoor air because of health impacts from acute to chronic exposure and its ability to degrade indoor air quality through oxidation chemistry. In seven four-hour experiments we measured O3 produced from a single filtered GUV222 lamp in a 31.5 m3 stainless steel chamber. Using an emission model, we determined an O3 generation rate of 19.4 ppbv h-1 ± 0.3 ppbv h-1 (equivalent to 1.22 mg h-1 ± 0.02 mg h-1). We estimated the fluence rate from the lamp using two methods: (1) chemical actinometry using tetrachloroethylene (actinometry) and (2) geometric projection of the irradiance field from radial and angular distribution measurements of the GUV222 lamp fluence (irradiance). Using the estimated lamp fluence rates of 2.2 microW cm-2 (actinometry) and 3.2 microW cm-2 (irradiance) we predicted O3 production in our chamber within 20 % of the average measured mixing ratio. Future studies should evaluate the indoor air quality impacts of GUV222 technologies.
More Related Videos
08:18Synthesis and Characterization of High c-axis ZnO Thin Film by Plasma Enhanced Chemical Vapor Deposition System and its UV Photodetector Application
Published on: October 3, 2015
10:06Microfluidic Fabrication Techniques for High-Pressure Testing of Microscale Supercritical CO2 Foam Transport in Fractured Unconventional Reservoirs
Published on: July 2, 2020
Related Concept Videos
UV–Vis Spectrometers
Oxidative Cleavage of Alkenes: Ozonolysis
Ozone is a symmetrical bent molecule stabilized by a resonance structure.
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
UV–Vis Spectroscopy: Molecular Electronic Transitions
Mutations
Chromosomal Alterations Are Large-Scale Mutations
While point mutations are changes in a single nucleotide in...