Related Experiment Video
Updated: Jun 30, 2025

Application of Straight-needle, Three-tailed, Knot-free, Peritoneal Sutures in Laparoscopic Transabdominal Preperitoneal Hernia Repair
Published on: November 12, 2021
Routine closed-suction drainage reduces seromas following totally extraperitoneal (TEP) inguinal hernia repair: A
Dimitrios Prassas1,2, Michael Zaczek1, Stephan Oliver David2
1Katholisches Klinikum Essen, Department of Surgery, Essen Germany.
Background:
The value of prophylactic closed-suction drainage in totally extraperitoneal inguinal hernia repair (TEP) is still a matter of controversy. We conducted a meta-analysis of studies examining postoperative seroma rates in patients with or without routine placement of closed-suction drainage tubes.
Methods:
A systematic literature search was conducted for trials comparing the outcome of TEP with or without routine drainage placement. Data regarding postoperative outcomes were extracted and compared by meta-analysis. The odds ratio and standardized mean differences with 95% confidence intervals were calculated.
Results:
Four studies were identified, involving a total of 1626 cases (Drain: n = 1251, no Drain: n = 375). There was a statistically significant difference noted between the 2 groups regarding postoperative seroma formation favoring the Drain group (odds ratio = 0.12; 95% confidence intervals [0.05, 0.29]; P < .001; 4 studies; I2 = 72%). For the remaining secondary endpoints postoperative urinary retention, recurrence, mesh infection and in-hospital length of stay no statistically significant difference was noted between the 2 study groups.
Conclusion:
Current evidence suggests that patients who underwent TEP with routine closed-suction drain placement developed significantly fewer seromas without any additional morbidity or prolongation of in-hospital stay.
More Related Videos
00:20A Case Series of Successful Abdominal Closure Utilizing a Novel Technique Combining a Mechanical Closure System with a Biologic Xenograft that Accelerates Wound Healing
Published on: July 4, 2019
10:52Laparoscopic Repair of Para-Esophageal Hernia Using Absorbable Biosynthetic Mesh
Published on: September 11, 2021
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...