Related Experiment Video
Updated: Jun 30, 2025

Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
A quantitative LC-MS/MS analysis of Xylazine, p-Fluorofentanyl, Fentanyl and Fentanyl-Related compounds in postmortem
Michael T Truver1, Sara C Brogan1, Emma A Jaeschke2
1Department of Pathology, Immunology and Laboratory Medicine, University of Florida College of Medicine, Gainesville, FL 32610, USA.
Abstract:
The purpose of this study was to develop and validate a method to quantitate the veterinary sedative xylazine as well as 4-anilino-N-phenethylpiperidine (4-ANPP), acetyl fentanyl, fentanyl, norfentanyl, and p-fluorofentanyl in blood utilizing liquid chromatography tandem mass spectrometry. This method also qualitatively monitors for the presence of o-fluorofentanyl and m-fluorofentanyl isomers. UCT Clean Screen® DAU extraction columns were utilized to isolate the analytes in postmortem blood samples. The extracts were eluted, evaporated, reconstituted, and then analyzed using a Waters Acquity™ UPLC coupled a triple quadrupole mass spectrometer. The lower limit of quantitation was determined to be 0.1 ng/mL for all analytes, except for xylazine (0.2 ng/mL). The upper limit of quantitation for all analytes was 100 ng/mL. No interferences from matrix, internal standard, or common drug analytes were observed. Bias (-13.1-4.6 %) and precision (-13.14-10.3 %) fell within the acceptable ± 20 % criteria range. Dilution integrity at x2, x10, and x100 was evaluated and all results were within ± 20 % of the target concentration. Processed extract stability was evaluated after 72 h and all results were within ± 20 % of the analyte initial concentration. Matrix effects were the most prominent with xylazine, but deemed acceptable as the deuterated internal standard also observed comparable enhancement. Analysis of 89 postmortem blood samples by this method resulted in positive results for fentanyl (0.27-66 ng/mL, n = 82), xylazine (0.24-958 ng/mL, n = 21), 4-ANPP (0.10-38 ng/mL, n = 72), acetyl fentanyl (0.18-1.5 ng/mL, n = 3), p-fluorofentanyl (0.11-33 ng/mL, n = 30), and norfentanyl (0.10-98 ng/mL, n = 73).
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
10:38Simultaneous Quantification of Selected Kynurenines Analyzed by Liquid Chromatography-Mass Spectrometry in Medium Collected from Cancer Cell Cultures
Published on: May 9, 2020