Impulse oscillometry in patients with pulmonary arterial hypertension: an exploratory study
Helena Jannuzzi Villas Bôas1, Ilma Aparecida Paschoal1, Mônica Corso Pereira1
1Departamento de Medicina Interna, Universidade de Campinas (UNICAMP), Campinas, SP, Brazil.
Introduction:
Studies suggest peripheral airway abnormalities in Pulmonary Arterial Hypertension (PAH). Impulse Oscillometry (IOS) is a noninvasive and sensitive technique for assessing the small airways. It evaluates the impedance of the respiratory system ‒ Resistance (R) and reactance (X) ‒ to a pulse of sound waves sent to the lungs, in a range of frequencies (5‒20 Hz).
Method:
Resistance variables: R5, R20, R5-R20 and reactance variables: AX (reactance area) and Fres (resonance frequency). The aim is to evaluate R and X in patients with idiopathic PAH (IPAH) and to investigate whether there is a correlation between IOS and spirometry.
Results:
Thirteen IPAH patients and 11 healthy subjects matched for sex and age underwent IOS and spirometry. IPAH patients had lower FVC and FEV1 values (p < 0.001), VEF1/CVF (p = 0.049) and FEF 25-75 (p = 0.006) than healthy patients. At IOS, IPAH patients showed lower tidal volumes and higher AX (p < 0.05) compared to healthy individuals, and 53.8 of patients had R5-R20 values ≥ 0.07 kPa/L/s. Correlation analysis: X5, AX, R5-R20 and Fres showed moderate correlation with FVC (p = 0.036 r = 0.585, p = 0.001 r = -0.687, p = 0.005 r = -0.726 and p = 0.027 r = -0.610); Fres (p = 0.012 r = -0.669) and AX (p = 0.006 r = -0.711) correlated with FEV1; [R5 and R20, (R5-R20)] also correlated with FEV1 (p < 0.001 r = -0.573, p = 0.020 r = -0.634 and p = 0.010 r = -0.683, respectively) in the IPAH group. There were also moderate correlations of FEF 25-75 % with Z5 (p = 0.041), R5 (p = 0.018), Fres (p = 0.043) and AX (p = 0.023).
Discussion:
Patients showed changes suggestive of increased resistance and reactance in the IOS compared to healthy individuals, and the IOS findings showed a good correlation with spirometry variables.
Related Concept Videos
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...