Related Experiment Video
Updated: Jun 30, 2025

Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
Optimizing the Glass Bead Sterilization Protocol Focusing on Removal of Organic and Bacterial Intraoperative
Keith Lewy1, Jonathan Bova1, Timothy A Erickson2
1Comparative Medicine Program, Texas A&M University, College Station, Texas.
Abstract:
Validated glass bead sterilization protocols to effectively sterilize rodent surgical instruments after bacterial exposure (for example, cecal contamination) are lacking. To refine current approaches, we added either a multienzyme detergent, neutral pH detergent, or chlorhexidine scrub step before glass bead sterilization of forceps or needle drivers exposed to cecal contents. We exposed sets of forceps and needle drivers to cecal contents, which were then air dried for 3 min. Immediately after, the instruments were wiped several times with a clean, dry paper towel. The contaminated tips were soaked in either a multienzyme or neutral pH detergent (t = 5 min), chlorhexidine scrub (t = 2 min), or no pretreatment solution. To further increase debris removal, instruments (from all groups) were brushed using a clean toothbrush. The nonpretreatment instruments were briefly soaked in saline before brushing. After being rinsed with sterile water, all instruments were exposed to a glass bead sterilizer for 60 s at 500 °F (260 °C). Sets were then swabbed for bacterial culturing. Swabs were plated onto either sheep blood agar (n = 23) or chocolate agar (n = 20) for aerobic culturing or Brucella agar (n = 20) for anaerobic culturing. A subset of instruments was sampled to determine organic material presence after treatment using an ATP luminometer (n = 21). Multiple agar types and bioluminescence were used to more deeply evaluate tool sterility and to differentiate the relative effectiveness of each protocol. From the saline group, only one pair of forceps yielded growth on Brucella agar, and 2 pairs yielded growth on chocolate agar. No other bacterial growth was observed. The use of a pretreatment agent also lowered overall organic contamination levels in needle drivers compared with using only saline. These results indicate that brushing instruments to mechanically remove debris from instruments is paramount to ensure sterility. However, a best practice would be to also use one of the pretreatment options used in this study.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Hand hygiene
Hand washing...

