Related Experiment Video
Updated: Jun 30, 2025

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Imaging of hypodense gliotic lesions in photon counting computed tomography using virtual monoenergetic images
Denise Schoenbeck1, Alexander Sacha1, Julius Henning Niehoff1
1Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Germany.
Objectives:
Glioses appear as hypodense lesions in non-contrast CT examinations of the head. Photon counting CT (PCCT) enables the calculation of virtual monoenergetic images (VMI). The aim of this study is to investigate in which VMI hypodense gliotic lesions can be delineated best.
Materials And Methods:
35 patients with an MRI-confirmed gliotic lesion and a non-contrast PCCT of the head were retrospectively included. All available VMI from 40 keV to 190 keV were calculated. In a quantitative analysis, conventional image quality parameters were calculated, in particular the contrast-to-noise ratio (CNR) of the hypodense lesion compared to the white matter. In a qualitative analysis, selected VMI were rated by experienced radiologists.
Results:
The absolute maximum of CNR was 8.12 ± 5.64 in the VMI 134 keV, in post hoc testing, there were significant differences in comparison to VMI with keV ≤110 and keV ≥180 (corrected p < .05). In the qualitative analysis, there were only very slight differences in the rating of the VMI with 66 keV, 80 keV, 100 keV, and 134 keV with overall low agreement between the readers.
Conclusions:
The quantitative superiority of VMI 134 keV for the delineation of hypodense gliotic lesions did not translate into a superiority in the qualitative analysis. Therefore, it remains uncertain if the reconstruction of a high keV VMIs for the detection of hypodense gliotic lesions is useful in everyday clinical practice. However, more studies, are necessary to further assess this issue.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

