Early and accurate diagnosis of steatotic liver by artificial intelligence (AI)-supported ultrasonography
Sergio Santoro1, Mohamad Khalil2, Hala Abdallah3
1PhD Program in Public Health, Clinical Medicine and Oncology, Department of Precision and Regenerative Medicine and Ionian Area (DiMePre-J), University of Bari "Aldo Moro", Bari, Italy; Eurisko Technology srl, Modugno, BA, Italy.
Objectives:
Steatotic liver disease is the most frequent chronic liver disease worldwide. Ultrasonography (US) is commonly employed for the assessment and diagnosis. Few information is available on the possible use of artificial intelligence (AI) to ameliorate the diagnostic accuracy of ultrasonography.
Materials And Methods:
An AI-based algorithm was developed using a dataset of US images. We prospectively enrolled 134 patients for algorithm validation. Patients underwent abdominal US and Proton Density Fat Fraction MRI scans (MRI-PDFF), assumed as reference technique. The hepatorenal index was manually calculated (HRIM) by 4 operators. An automatic hepatorenal index (HRIA) was obtained by the algorithm. The accuracy of HRIA to discriminate steatosis grades was evaluated by ROC analysis using MRI-PDFF cut-offs.
Results:
Overweight was 40 % of subjects (BMI 26.4 kg/cm2). The median HRIA was 1.11 (IQR 0.32) and the average of 4 manually calculated HRIM was 1.08 (IQR 0.26), with a 15 % inter-operator variability. Both HRIA (R = 0.79, P < 0.0001) and HRIM (R = 0.69, P < 0.0001) significantly correlated with liver fat percentage (MRI-PDFF). According to MRI-PDFF, 32 % of enrolled subjects had steatosis. Discrimination capacity by AUC between patient with steatosis and patient without steatosis was better for HRIA than HRIM (AUC: 0.87 vs. 0.82, respectively). ROC analysis showed an AUC = 0.98 for HRIA with 1.64 cut-off in distinguishing between mild and moderate/severe groups.
Conclusions:
The use of AI improves accuracy and speed of ultrasonography in the diagnosis of liver steatosis. Further studies should evaluate the routine use of this technique in the management of liver steatosis at high cardio-metabolic risk.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...