Related Experiment Video
Updated: Jun 30, 2025

Biomechanical Testing of Murine Tendons
Published on: October 15, 2019
Assessing site-specificity of the biomechanical properties of hamstring aponeuroses using MyotonPRO: A cadaveric
Xiyao Shan1, Shun Otsuka1, Tomohito Okubo1
1Department of Anatomy, School of Medicine, Aichi Medical University, Nagakute, Aichi, Japan.
Background:
Hamstring muscles are the most frequently reported sites of muscle strain injuries, especially near the bi-articular muscles' myotendinous junction, where aponeurosis provides a connective tissue network linking muscle fibers to the tendon. This study aimed to investigate the reliability and site-specific differences of hamstring aponeuroses under different conditions (formalin and urea) using MyotonPRO.
Methods:
Eight hamstring muscle groups were dissected from four human cadavers (two males and two females) aged 83-93 years. Measurements of the mechanical properties of the aponeuroses from the superficial and deep regions of biceps femoris long head, semitendinosus, and semimembranosus (after formalin solution immersion) were done using MyotonPRO (intra-rater reliability was examined within a 24-h interval), following which the hamstring aponeuroses were measured using a similar procedure after urea solution immersion.
Findings:
Test-retest (intra-rater) results revealed that the MyotonPRO measurement of tone, stiffness, relaxation, and creep of cadaveric aponeuroses presented good to excellent reliability (ICC: 0.86 to 0.98). There were no significant differences in tone, stiffness, elasticity, relaxation, and creep among the six sites of hamstring aponeuroses under both formalin and urea conditions. Significant differences between formalin and urea conditions were found in the tone, stiffness, relaxation, and creep of hamstring aponeuroses (P < 0.05).
Interpretation:
These results suggested that the biomechanical properties of hamstring aponeuroses showed homogeneity between the sites using MyotonPRO. Urea solution could potentially neutralize the effect of formalin on the biomechanical properties of cadaveric muscle-aponeurosis-tendon units. The present findings might influence the design of subsequent cadaveric studies on hamstring muscle strains.

