Related Experiment Video
Updated: Jun 30, 2025

Author Spotlight: Evaluating Clinicians' Adoption of Ultrasound-Guided Vascular Cannulation Through Simulation Training
Published on: August 9, 2024
Radial Arterial Cannulation by Ultrasound-Guided Dynamic Needle-Tip Positioning Using the Short-Axis Out-of-Plane
Bharath Kumar Mesa1, Mamta Sinha1, Mayank Kumar1
1Anesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND.
Abstract:
Introduction Radial artery cannulation is a commonly performed invasive procedure for assessing a patient's hemodynamic status and collecting blood samples. Ultrasound guidance has shown benefits in improving the success rate of first-attempt cannulation. Two main approaches, short-axis out-of-plane (SAOOP) and long-axis in-plane (LAIP), are commonly used. A modified technique called dynamic needle-tip positioning (DNTP) using the short-axis out-of-plane approach has been reported to enhance arterial catheterization. This study aims to compare the first-attempt success rates of radial artery cannulation using the two techniques, DNTP versus LAIP, along with overall success rates, cannulation time, and number of attempts. Methods This prospective, randomized, controlled, clinical study was conducted after obtaining clearance from the Institute Ethics Committee of AIIMS, Raipur. Ninety-six patients between the ages of 18 and 50 years, undergoing elective surgery under general anesthesia, and required radial arterial cannulation were randomized and equally allocated into two groups as the LAIP and DNTP approaches. The first-pass success rate, time to achieve successful cannulation, number of attempts needed, overall success rate within five minutes, and potential complications, such as thrombosis, vasospasm, and hematoma, were recorded. Results A total of 96 patients were included, with 48 in the LAIP group and 48 in the DNTP group. The DNTP group showed statistically significant advantages over the LAIP group, with a higher first-pass success rate (97.9% vs. 83.3%; p = 0.014) and shorter time to achieve successful cannulation (9.29±3.79 vs. 26.16±20.22 seconds; p = 0.001). Conclusion The ultrasound-guided short-axis DNTP technique for radial artery cannulation demonstrated a significant advantage as compared to the LAIP technique. The DNTP technique resulted in higher first-attempt cannulation success and shorter cannulation time.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
07:30Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique
Published on: April 1, 2022
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: