Related Experiment Video
Updated: Jun 30, 2025

Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Enhancing Nuclear Medicine Practice in Saudi Arabia: Advocating for Comprehensive Guidelines and Local Diagnostic
Sarah K Albahiti1, Mawya Khafaji2, Nadiya Batawil3
1Radiology, King Abdulaziz University Hospital, Jeddah, SAU.
Introduction:
Diagnostic reference levels (DRLs) were initially introduced by the International Commission on Radiation Protection (ICRP). It refers to the measured quantity of administered activity (MBq) in nuclear medicine imaging studies and is a type of investigation level. DRL is recommended to prevent excessive radiation exposure to patients while maintaining adequate image quality. It should not be implemented as a dose constraint or dose limit. The Saudi Food and Drug Authority (SFDA) is the primary government body responsible for reporting national diagnostic reference levels (NDRLs) for diagnostic medical imaging technologies in Saudi Arabia. Only NDRLs for computed tomography, general X-ray, and mammography have been published and enforced locally. This study aims to establish local DRLs for nuclear medicine imaging procedures at King Abdulaziz University Hospital, Saudi Arabia, preparing for compliance proof once required by local authorities.
Method:
Data were collected from all machines, and six common protocols were studied, with data from 50 patients of standard body size for each identified protocol. The study was conducted retrospectively, and the 50th percentile was then calculated for each scan.
Results:
Both protocols for renal scans administered the lowest doses to patients (130 MBq and 148 MBq), respectively. The highest dose administered to patients was found to be in bone scans (1110 MBq).
Conclusion:
The study establishes local DRLs for nuclear medicine imaging in our institution. Median activity dosages in renal, thyroid, and parathyroid imaging were comparable to locally and internationally published DRLs. However, they are higher in cardiac and bone imaging compared to local Saudi DRL and DRL in the European Union and the USA, likely due to the adopted protocols. These highlight the need for modifying the protocols to fulfill optimization efforts. These findings serve as a foundation for compliance with future regulatory requirements, ensuring patient safety and maintaining imaging quality in Saudi healthcare.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...