Related Experiment Video
Updated: Jul 19, 2026

Failure Analysis of Batteries Using Synchrotron-based Hard X-ray Microtomography
Published on: August 26, 2015
Exposure Assessment Study on Lithium-Ion Battery Fire in Explosion Test Room in Battery Testing Facility
Mi Sung Jo1, Hoi Pin Kim2, Boo Wook Kim3
1HCTm, Icheon, Republic of Korea.
Abstract:
A lithium-ion battery is a rechargeable battery that uses the reversible reduction of lithium ions to store energy and is the predominant battery type in many industrial and consumer electronics. The lithium-ion batteries are essential to ensure they operate safely. We conducted an exposure assessment five days after a fire in a battery-testing facility. We assessed some of the potentially hazardous materials after a lithium-ion battery fire. We sampled total suspended particles, hydrogen fluoride, and lithium with real-time monitoring of particulate matter (PM) 1, 2.5, and 10 micrometers (μm). The area sampling results indicated that primary potential hazardous materials such as dust, hydrogen fluoride, and lithium were below the recommended limits suggested by the Korean Ministry of Labor and the American Conference of Governmental Industrial Hygienists Threshold Limit Values. Based on our assessment, workers were allowed to return to work.
More Related Videos
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
08:42In Situ Gas Analysis and Fire Characterization of Lithium-Ion Cells During Thermal Runaway Using an Environmental Chamber
Published on: March 31, 2023