A Passive Ankle Dorsiflexion Testing System for an In Vivo Model of Overuse-induced Tendinopathy
Pooja H Chainani1, Patrick M Williamson1, Diana Yeritsyan2
1Musculoskeletal Translational Innovation Initiative, Carl J. Shapiro Department of Orthopaedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School; Mechanical Engineering Department, Boston University.
Abstract:
Tendinopathy is a chronic tendon condition that results in pain and loss of function and is caused by repeated overload of the tendon and limited recovery time. This protocol describes a testing system that cyclically applies mechanical loads via passive dorsiflexion to the rat Achilles tendon. The custom-written code consists of pre- and post-cyclic loading measurements to assess the effects of the loading protocol along with the feedback control-based cyclic fatigue loading regimen. We used 25 Sprague-Dawley rats for this study, with 5 rats per group receiving either 500, 1,000, 2,000, 3,600, or 7,200 cycles of fatigue loads. The percentage differences between the pre- and post-cyclic loading measurements of the hysteresis, peak stress, and loading and unloading moduli were calculated. The results demonstrate that the system can induce varying degrees of damage to the Achilles tendon based on the number of loads applied. This system offers an innovative approach to apply quantified and physiological varying degrees of cyclic loads to the Achilles tendon for an in vivo model of fatigue-induced overuse tendon injury.