Reference Data for a Quick Speech-in-Noise Hearing Test in the French Language
Julie Bestel1, Daniel Pressnitzer2, Mathieu Robier3
1Audilab Ressources, Saint-Pierre-des-Corps, France.
Introduction:
Difficulty in understanding speech in noise is the most common complaint of people with hearing impairment. Thus, there is a need for tests of speech-in-noise ability in clinical settings, which have to be evaluated for each language. Here, a reference dataset is presented for a quick speech-in-noise test in the French language (Vocale Rapide dans le Bruit, VRB; Leclercq, Renard, & Vincent, 2018).
Methods:
A large cohort (N = 641) was tested in a nationwide multicentric study. The cohort comprised normal-hearing individuals and individuals with a broad range of symmetrical hearing losses. Short everyday sentences embedded in babble noise were presented over a spatial array of loudspeakers. Speech level was kept constant, while noise level was progressively increased over a range of signal-to-noise ratios. The signal-to-noise ratio for which 50% of keywords could be correctly reported (speech reception threshold, SRT) was derived from psychometric functions. Other audiometric measures were collected for the cohort, such as audiograms and speech-in-quiet performance.
Results:
The VRB test was both sensitive and reliable, as shown by the steep slope of the psychometric functions and by the high test-retest consistency across sentence lists. Correlation analyses showed that pure tone averages derived from the audiograms explained 74% of the SRT variance over the whole cohort, but only 29% for individuals with clinically normal audiograms. SRTs were then compared to recent guidelines from the French Society of Audiology [Eur Ann Otorhinolaryngol Head Neck Dis. 2022;139(1):21-7]. Among individuals who would not have qualified for hearing aid prescription based on their audiogram or speech intelligibility in quiet, 18.4% were now eligible as they displayed SRTs in noise impaired by 3 dB or more. For individuals with borderline audiograms, between 20 dB HL and 30 dB HL, the prevalence of impaired SRTs increased to 71.4%. Finally, even though five lists are recommended for clinical use, a minute-long screening using only one VRB list detected 98.6% of impaired SRTs.
Conclusion:
The reference data suggest that VRB testing can be used to identify individuals with speech-in-noise impairment.