Related Experiment Video
Updated: Jun 30, 2025

Author Spotlight: Understanding Age-Related Macular Degeneration Pathophysiology with QAF Workflow
Published on: May 26, 2023
Retinal sensitivity changes in early/intermediate AMD: a systematic review and meta-analysis of visual field testing
Matt Trinh1, Michael Kalloniatis1,2, Sieu K Khuu1
1School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia.
Abstract:
Visual fields under mesopic and scotopic lighting are increasingly being used for macular functional assessment. This review evaluates its statistical significance and clinical relevance, and the optimal testing protocol for early/intermediate age-related macular degeneration (AMD). PubMed and Embase were searched from inception to 14/05/2022. All quality assessments were performed according to GRADE guidelines. The primary outcome was global mean sensitivity (MS), further meta-analysed by: AMD classification scheme, device, test pattern, mesopic/scotopic lighting, stimuli size/chromaticity, pupil dilation, testing radius (area), background luminance, adaptation time, AMD severity, reticular pseudodrusen presence, and follow-up visit. From 1489 studies screened, 42 observational study results contributed to the primary meta-analysis. Supported by moderate GRADE certainty of the evidence, global MS was significantly reduced across all devices under mesopic and scotopic lighting with large effect size (-0.9 [-1.04, -0.75] Hedge's g, P < 0.0001). The device (P < 0.01) and lighting (P < 0.05) used were the only modifiable factors affecting global MS, whereby the mesopic MP-1 and MAIA produced the largest effect sizes and exceeded test-retest variabilities. Global MS was significantly affected by AMD severity (intermediate versus early AMD; -0.58 [-0.88, -0.29] Hedge's g or -2.55 [3.62, -1.47] MAIA-dB) and at follow-up visit (versus baseline; -0.62 [-0.84, -0.41] Hedge's g or -1.61[-2.69, -0.54] MAIA-dB). Magnitudes of retinal sensitivity changes in early/intermediate AMD are clinically relevant for the MP-1 and MAIA devices under mesopic lighting within the central 10° radius. Other factors including pupil dilation and dark adaptation did not significantly affect global MS in early/intermediate AMD.
More Related Videos
10:14Author Spotlight: Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration
Published on: May 26, 2023
09:24A Protocol to Evaluate and Quantify Retinal Pigmented Epithelium Pathologies in Mouse Models of Age-Related Macular Degeneration
Published on: March 10, 2023