Background:
Adequate cough or exsufflation flow can indicate an option for safe tracheostomy decannulation to noninvasive management. Cough peak flow via the upper airways with the tube capped is an outcome predictor for decannulation readiness in patients with neuromuscular impairment. However, this threshold value is typically measured with tracheotomy tube removed, which is not acceptable culturally in China. The aim of this study was to assess the feasibility and safety of using cough flow measured with tracheostomy tube and speaking valve (CFSV) > 100 L/min as a cutoff value for decannulation.
Study Design:
Prospective observational study conducted between January 2019 and September 2022 in a tertiary rehabilitation hospital.
Methods:
Patients with prolonged tracheostomy tube placement were referred for screening. Each patient was assessed using a standardized tracheostomy decannulation protocol, in which CFSV greater than 100 L/min indicated that the patients' cough ability was sufficient for decannulation. Patients whose CFSV matched the threshold value and other protocol criteria were decannulated, and the reintubation and mortality rates were followed-up for 6 months.
Results:
A total of 218 patients were screened and 193 patients were included. A total of 105 patients underwent decannulation, 103 patients were decannulated successfully, and 2 patients decannulated failure, required reinsertion of the tracheostomy tube within 48 h (failure rate 1.9%). Three patients required reinsertion or translaryngeal intubation within 6 months.
Conclusions:
CFSV greater than 100 L/min could be a reliable threshold value for successful decannulation in patients with various primary diseases with a tracheostomy tube.
Trial Registration:
This observational study was not registered online.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...