Related Experiment Video
Updated: Aug 16, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Plastic versus metal stents for transmural drainage of walled-off necrosis with significant solid debris: a
Rinkal Kakadiya1, Gaurav Muktesh1, Jayanta Samanta1
1Gastroenterology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Abstract:
Background and study aims Recently, larger-caliber metal stents have been increasingly used, resulting in higher efficacy in walled-off necrosis (WON) with more solid debris. However, none of the trials have included WON with significant solid debris. The aim of this study was to compare plastic stents and metal stents for drainage of symptomatic WON with significant solid debris (≥20%). Patients and methods We conducted a single-center, open-label, noninferiority trial including 48 patients. The primary endpoint was treatment success. Secondary outcomes were technical success, total number of procedures, adverse events (AEs), duration of procedure, and treatment failure. All the outcomes were assessed at 3 weeks after drainage. Patients were followed up for 3 months to assess recurrence. Results Treatment succeeded in 21 of 24 patients (87.5%) and 20 of 24 patients (83.3%) in the metal and plastic stent groups, respectively with P =1.05 (95% confidence interval 0.81-1.39). Assuming 10% non-inferiority margin, P <0.001 for non-inferiority, suggesting that plastic stents are non-inferior to metal stents. The technical success rate was 100%. Procedure duration was significantly shorter in the metal stent group (12.95±5.3 minutes versus 29.77±6.6 minutes, P <0.001). The number of total procedures was comparable (2.8±1 vs 2.2±1, P =0.097). There were more minor AEs in plastic stent arm but no significant difference between the two groups. A single asymptomatic recurrence was observed in the metal stent arm. Conclusions Plastic stents are not inferior to metal stents for WON drainage with significant solid debris. However, larger sample-size studies are needed to make definite conclusions.
More Related Videos
11:07Biodegradable Magnesium Stent Treatment of Saccular Aneurysms in a Rat Model - Introduction of the Surgical Technique
Published on: October 1, 2017
05:41Using a Cell-Tracer Injection to Investigate the Origin of Neointima-Forming Cells in a Rat Saccular Side Wall Model
Published on: March 16, 2022
Related Concept Videos
Masonry Curtain Walls
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...