Krishna Kattel1, Jeffrey D Clogston2
1Nanotechnology Characterization Laboratory, Cancer Research Technology Program, Frederick National Laboratory for Cancer Research, Frederick, MD, USA.
Abstract:
Various organic solvents are widely used in the manufacturing, processing, and purification of drug substances, drug products, formulations, excipients, etc. These solvents must be removed to the lowest amount permitted, as they do not possess any therapeutic advantages and may cause undesirable toxicities. Therefore, a rapid and sensitive analytical method for the quantitation of residual solvents is needed. The following chapter presents a static headspace gas chromatographic (HSGC) method for determining the concentration of common residual solvents in various nanoformulations. An efficient and sensitive HSGC method has been developed using PerkinElmer's headspace autosampler/gas chromatographic system with a flame ionization detector (FID) and validated according to the International Conference for Harmonization (ICH) guideline Q3C. The method validation indicates that the method is specific, linear, accurate, precise, and sensitive for the analyzed solvents. The method is suitable for the analysis of 13 residual solvents (methanol, ethanol, acetone, diethyl ether, 2-propanol, acetonitrile, 1-propanol, ethyl acetate, tetrahydrofuran, dichloromethane, chloroform, 1-butanol, and pyridine) and utilizes an Elite 624 Crossbond 6% cyanopropylphenyl, 94% dimethylpolysiloxanes column with helium as a carrier gas.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
11:06GC-based Detection of Aldononitrile Acetate Derivatized Glucosamine and Muramic Acid for Microbial Residue Determination in Soil
Published on: May 19, 2012
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Volatilization
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...