A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Evaluation of vital signs through a mobile application in patients with heart failure: a opportunity for remote
Lucrecia M Burgos1, Franco Ballari2, Maximiliano Massa2
1Servicio de Insuficiencia Cardiaca, Hipertensión Pulmonar y Trasplante Cardiaco.
Background:
Virtual consultations have increased exponentially, but a limitation is the inability to assess vital signs (VS). This is particularly useful in patients with heart failure (HF) for titrating prognosis-modifying medication. This issue could potentially be addressed by a tool capable of measuring blood pressure (BP) and heart rate (HR) accurately, remotely, and conveniently. Mobile phones equipped with transdermal optical imaging technology could meet these requirements.
Objective:
To evaluate the accuracy of a transdermal optical imaging-based app for estimating VS compared to clinical assessment in patients with HF.
Methods:
A prospective cohort study included patients evaluated in an HF outpatient unit between February and April 2022. BP and HR were simultaneously assessed using the app and clinical examination (BP with an automated sphygmomanometer and HR by brachial palpation). Three measurements were taken by both the app and clinic for each patient, by two independent blinded physicians.
Results:
Thirty patients were included, with 540 measurements of BP and HR. The mean age was 66 (± 13) years, 53.3% were male. The mean left ventricular ejection fraction was 37 ± 15, with 63.3% having previous hospitalizations for HF, and 63.4% in NYHA class II-III. The mean difference between the app measurement and its clinical reference measurement was 3.6 ± 0.5 mmHg for systolic BP (SBP), 0.9 ± -0.2 mmHg for diastolic BP (DBP), and 0.2 ± 0.4 bpm for HR. When averaging the paired mean differences for each patient, the mean across the 30 patients was 2 ± 6 mmHg for SBP, -0.14 ± 4.6 mmHg for DBP, and 0.23 ± 4 bpm for HR.
Conclusion:
The estimation of BP and HR by an app with transdermal optical imaging technology was comparable to non-invasive measurement in patients with HF and met the precision criteria for BP measurement in this preliminary study. The use of this new transdermal optical imaging technology provides promising data, which should be corroborated in larger cohorts.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...