Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
442
Accuracy of Wearable Heart Rate Monitors During Exercise in Sinus Rhythm and Atrial Fibrillation
Ryan Quinn1, Nathan Leader2, Gerald Lebovic3
1St Michael's Hospital, Unity Health Toronto, Toronto, Ontario, Canada.
Journal of the American College of Cardiology
|March 20, 2024
Abstract
No abstract available in PubMed .
Related Concept Videos
Pulse rhythm
796
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
796
Disturbances in Heart Rhythm
952
Arrhythmia or dysrhythmia refers to an abnormal heart rhythm caused by a defect in the heart's conduction system. It can cause the heart to beat irregularly, too quickly, or too slowly, leading to symptoms like chest pain, shortness of breath, and fainting. Factors such as stress, caffeine, alcohol, nicotine, cocaine, certain drugs, congenital defects, diseases, and electrolyte abnormalities can trigger arrhythmias.
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
952
Exercise and Cardiovascular Response
804
Exercise significantly impacts cardiovascular response, which is crucial for understanding patient health and designing effective treatment plans.
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
804
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
213
Arrhythmias are disturbances in the heart's rhythm that lead to abnormal heartbeats. These irregularities can originate from different parts of the heart and are classified based on their origin and nature.
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
213
Equipments Used To Measure Blood Pressure
967
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
967
Errors occurring during blood pressure monitoring
721
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
721