Evaluation of residual dentin thickness using quantitative light-induced fluorescence technology
Kiljoo Jung1, Stephanie Myeong Choi1, Hoi-In Jung2
1Microscope Center, Department of Conservative Dentistry and Oral Science Research Center, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.
Odontology
|March 21, 2024
Summary
This study found a significant positive correlation between residual dentin thickness and quantitative light-induced fluorescence (QLF) values. These findings highlight the relationship between dentin thickness and QLF measurements, regardless of the operator.
Area of Science:
- Dental Materials Science
- Diagnostic Technologies in Dentistry
- Cariology and Operative Dentistry
Background:
- Residual dentin thickness (RDT) is a critical factor in restorative dentistry, influencing pulp vitality and treatment outcomes.
- Quantitative light-induced fluorescence (QLF) is a non-invasive technique used to detect and quantify demineralization and remineralization in tooth structure.
- Understanding the relationship between RDT and QLF can potentially improve diagnostic accuracy and treatment planning.
Purpose of the Study:
- To investigate the correlation between residual dentin thickness (RDT) and quantitative light-induced fluorescence (QLF) values.
- To analyze the tendencies of this correlation in both simulated vital (filled) and non-vital (unfilled) pulp conditions.
Main Methods:
- Forty extracted human molars were divided into filled (simulated vital pulp) and unfilled groups.
- Teeth were sectioned, and samples with RDTs of 2 mm, 1 mm, and 0.5 mm were prepared.
- Quantitative light-induced fluorescence (QLF) images were captured using the QLF-D Biluminator™ 2+ system, and ΔF values were analyzed.
Main Results:
- A significant positive correlation was observed between residual dentin thickness and ΔF values (P < 0.05).
- Mean ΔF values showed a trend of increasing negativity with decreasing RDT in both groups.
- High intraclass correlation coefficients (0.831 for filled, 0.917 for unfilled) indicated excellent inter-operator reliability.
Conclusions:
- Residual dentin thickness and quantitative light-induced fluorescence (QLF) ΔF values are significantly and positively correlated.
- This correlation is robust and consistent across different operators, suggesting the reliability of QLF in assessing RDT-related changes.
- The findings support the potential use of QLF as a diagnostic tool to evaluate conditions influenced by residual dentin thickness.
Keywords:
Pulp exposurePulp statusQuantitative light-induced fluorescence technologyResidual dentin thickness