Positive correlation between echocardiographic tricuspid E peak velocity and central venous pressure in dogs: A
Zahra Jafari-Giv1, Alireza Vajhi1, Saeed Farzad-Mohajeri1,2
1Department of Surgery and Radiology, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
Abstract:
In the absence of vascular obstruction, central venous pressure (CVP) is a hydrostatic pressure in the cranial and caudal vena cava, providing valuable information about cardiac function and intravascular volume status. It is also a component in evaluating volume resuscitation in patients with septic shock and monitoring patients with right heart disease, pericardial disease, or volume depletion. Central venous pressure is calculated in dogs by invasive central venous catheterization, which is considered high-risk and impractical in critically ill patients. This study aimed to investigate the feasibility of using echocardiographic tricuspid E/E' as a noninvasive method to estimate CVP in anesthetized healthy dogs under controlled hypovolemic conditions. Ten male mixed-breed dogs were included in the study after a thorough health assessment. For hypovolemia induction, blood withdrawal was performed, and echocardiographic factors of the tricuspid valve, including peak E and E' velocities, were measured during CVP reduction. Repeated measures analysis of variance and Bonferroni post hoc tests were employed to compare the average difference between measured echocardiographic indices and CVP values derived from catheterization and intermittent measurement methods. Spearman's ρ correlation coefficient was used to evaluate the correlation between echocardiographic indices and CVP. E peak velocity had a significant negative correlation with venous blood pressure phases (r = -0.44, P = .001), indicating a decrease in peak E velocity with progressive CVP reduction. However, tricuspid valve E' peak velocity and E/E' did not correlate with CVP, suggesting that these parameters are not reliable for CVP estimation in dogs.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Measurement of Blood Pressure
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...