Related Experiment Video
Updated: Jun 30, 2025

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Analysis of vitamin D and its metabolites in biological samples - Part I: Optimization and comparison of UHPSFC-MS/MS
Veronika Pilařová1, Bárbara Socas-Rodríguez2, Lucie Nováková3
1Lund University, Department of Chemistry, Centre for Analysis and Synthesis, Lund, Sweden; Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Hradec Králové, Czech Republic.
Abstract:
Fat-soluble vitamin D is an essential bioactive compound important for human health. Insufficient vitamin D levels can result not only in bone disease but also in other disorders, such as cancer, metabolic disorders, and diseases related to poor immune function. The current methods commonly used for vitamin D analysis are often applied to determine the levels of the most abundant metabolite in plasma, i.e., 25-OH-D2/D3. These methods do not consider the presence of other hydroxylated and esterified metabolites, including isomers and epimers, which are typically found in low concentrations. In this study, we developed a fast and selective ultra-high performance supercritical fluid chromatography (UHPSFC) method using a 150 mm long 1-amino anthracene (1-AA) column and a mobile phase consisting of carbon dioxide and methanol/isopropanol (1/1, v/v) mixed with 8 % water. After thorough optimization of column temperature and back pressure, the separation of four vitamin D3 esters, vitamin D3 and D2, and eight mono- and di-hydroxylated metabolites, including three groups of isomers, was achieved in 10 min. Two ion sources, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization optimized within this study, were compared in tandem mass spectrometry (MS/MS) detection. No significant sensitivity differences were observed. Subsequently, the same 1-AA column chemistry was examined in ultra-high performance liquid chromatography (UHPLC) as the stationary phase that could hypothetically bring different selectivity in the separation of vitamin D and its metabolites. However, this hypothesis was rejected, and C18 was used as a stationary phase in the final optimized UHPLC-MS/MS method. Despite detailed optimization, the final 15 min UHPLC method was not able to separate di-hydroxylated isomers of vitamin D3, while it enabled better resolution of esterified forms compared to UHPSFC. Optimized methods provided similar repeatability of retention times and peak areas, with RSD < 2 % and 10 %, respectively. The lowest limits of quantification were in the range of 1.2 - 4.9 ng/mL for UHPSFC-APCI-MS/MS, while for UHPLC-APCI-MS/MS, they were typically in the range of 2.6 - 9.6 ng/mL. Based on the obtained results, the UHPSFC-APCI-MS/MS method was the most promising approach for fast, selective, and sensitive analysis that could be applied in the analysis of biological samples with emphasis on the separation of both hydroxylated and esterified metabolites, including isomeric forms.
More Related Videos
05:03Author Spotlight: Investigating Physiological Functions of Vitamin A Transporters Using HPLC-Based Vitamin A Profiling
Published on: December 27, 2024
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013