Assessing the Accuracy of Systolic Aortic Pressure Estimation From a Brachial Cuff Alone: A Comparison With Radial
Denis Chemla1, Davide Agnoletti2,3, Pierre Attal4
1INSERM UMRS 999, Department of Cardiovascular Physiology, Hôpital Marie Lannelongue, 133 Avenue de la Résistance, 92350 Le Plessis-Robinson, France.
Background:
A novel method for estimating central systolic aortic pressure (cSAP) has emerged, relying solely on the peripheral mean (MBP) and diastolic (DBP) blood pressures. We aimed to assess the accuracy of this Direct Central Blood Pressure estimation using cuff alone (DCBPcuff = MBP2/DBP) in comparison to the use of a generalized transfer function to derive cSAP from radial tonometry (cSAPtono).
Methods:
This retrospective analysis involved the International Database of Central Arterial Properties for Risk Stratification (IDCARS) data (Aparicio et al., Am J Hypertens 2022). The dataset encompassed 10,930 subjects from 13 longitudinal cohort studies worldwide (54.8% women; median age 46.0 years; office hypertension: 40.1%; treated: 61.0%), documenting cSAPtono via SphygmoCor calibrated against brachial systolic BP (SBP) and DBP. Our analysis focused on aggregate group data from 12/13 studies (89% patients) where a full BP dataset was available. A 35% form factor was used to estimate MBP = (DBP + (0.35 × (SBP-DBP)), from which DCBPcuff was derived. The predefined acceptable error for cSAPtono estimation was set at ≤ 5 mm Hg.
Results:
The cSAPtono values ranged from 103.8-127.0 mm Hg (n = 12). The error between DCBPcuff and cSAPtono was 0.2 ± 1.4 mm Hg, with no influence of the mean. Errors ranged from -1.8 to 2.9 mm Hg across studies. No significant difference in errors was observed between BP measurements obtained via oscillometry (n = 9) vs. auscultation (n = 3) (P = 0.50).
Conclusions:
Using published aggregate group data and a 35% form factor, DCBPcuff demonstrated remarkable accuracy in estimating cSAPtono, regardless of the BP measurement technique. However, given that individual BP values were unavailable, further documentation is required to establish DCBPcuff's precision.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...