Related Experiment Video
Updated: Jun 30, 2025

Photoacoustic Cystography
Published on: June 11, 2013
Pancreatic cyst prevalence and detection with photon counting CT compared with conventional energy integrating
Bari Dane1, Jesi Kim1, Kun Qian2
1Department of Radiology, NYU Langone Health, 660 1(st) Avenue, New York, NY 10016.
Purpose:
To calculate the prevalence of pancreatic cysts on photon counting CT (PCCT) and compare with that of 128-slice conventional energy-integrating detector CT (EIDCT).
Method:
A retrospective single institution database search identified all contrast-enhanced abdominal CT examinations performed at an outpatient facility that has both a PCCT and EIDCT between 4/11/2022 and 7/26/2022. The presence and size of pancreatic cysts were recorded. In patients with PCCT reported pancreatic cysts, prior CT imaging (EIDCT) was reviewed for reported pancreatic cysts. Fisher's exact test was used to compare the pancreatic cyst detection rate for PCCT and EIDCT. Wilcoxon rank sum test was used to compare cyst size and patient age. A p <.05 indicated statistical significance.
Results:
2494 patients were included. Our pancreatic cyst detection rate was 4.9 % (49/1009) with PCCT and 3.0 % (44/1485) for EIDCT (p =.017). For CT angiograms, pancreatic cysts were detected in 6.6 % (21/319) with PCCT and 0.0 % (0/141) with EIDCT (p <.001). Pancreatic cyst detection rate was not statistically different for portal venous, enterography, renal mass, pancreas, 3-phase liver, or venogram protocols (all p >.05). Mean[SD] pancreatic cyst size was 13.7[9.7]mm for PCCT and 15.3[14.7] for EIDCT (p =.95). 55.1 % (27/49) of PCCT and 61.4 % (27/44) of EIDCT that described pancreatic cysts had prior contrast-enhanced EIDCTs. Of these, 40.7 % (11/27) of PCCT and 14.8 % (4/27) of EIDCT described pancreatic cysts were not previously reported (p =.027).
Conclusions:
Photon-counting CT afforded greater pancreatic cyst detection than conventional energy-integrating detector CT, particularly with CT angiograms.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...