Related Experiment Video
Updated: Jun 30, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Radiation exposure associated with computed tomography for pediatric urolithiasis evaluation: A scoping review of the
Wyatt MacNevin1, Michael Chua2, Mareen Sarah Kraus3
1Department of Urology, Dalhousie University, Halifax, Nova Scotia, B3H 2Y9, Canada.
Introduction:
Computed tomography (CT) imaging is used for assessment of pediatric urolithiasis in cases where ultrasound is inconclusive. The utility of CT imaging must be considered alongside the potential risks of radiation exposure in this patient population due to the increased risk of cancer development. The purpose of this review is to investigate the radiation exposure associated with standard-dose and low-dose computed tomography (CT) imaging for the assessment of pediatric urolithiasis.
Methods:
A scoping literature review over a 23 year period between 2000 and 2023 was conducted of all English-language studies reporting on the use of non-contrast CT imaging for assessment of pediatric urolithiasis. Patients that were specified as pediatric with age ≤20 years at time of intervention and undergoing standard-dose or low/ultra-low-dose CT were included. Low-dose and ultra-low-dose CT were defined as a radiation dose ≤3.0 mSv and ≤1.9 mSv, respectively.
Results:
A total of 8121 articles were identified and after screening, 6 articles representing 309 patients were included in this scoping review. Of the articles reviewed, standard non-contrast CT radiation doses for pediatric urolithiasis evaluation ranged from 2.9 to 5.5 mSv and low-dose CT radiation dose was reported to be 1.0-2.72 mSv. Only 2 studies directly evaluated low-dose CT imaging compared to standard-dose CT imaging for pediatric urolithiasis assessment. Radiation reduction approaches did not negatively impact urolithiasis detection or characterization in 2 studies reviewed.
Conclusions:
CT radiation doses for suspected or known pediatric urolithiasis are underreported and vary greatly with underutilization of low-dose/ultra-dose protocols for pediatric urolithiasis especially in comparison to the adult population. Results from this scoping review support that low-dose CTprotocols for pediatric stone disease are feasible to reduce radiation exposure.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...