Related Experiment Video
Updated: Jun 18, 2026

Standardized Model of Ventricular Fibrillation and Advanced Cardiac Life Support in Swine
Published on: January 30, 2020
The Importance of Early Femoral Access When REBOA Catheter Must Be Removed Prior to Hemorrhage Control
Michele N Fiorentino1, Michael C Smith1, Stephen P Gondek1
1Division of Acute Care Surgery, Department of Surgery, Vanderbilt University Medical Center, Nashville, TN, USA.
Abstract:
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a tool for hemorrhage control. We describe a case where the REBOA Catheter needed to be removed prior to hemorrhage control. The patient is a 40-year-old man that presented following motor vehicle collision. A REBOA Catheter was placed via the right common femoral artery (CFA). CT scan demonstrated extravasation from the left inferior epigastric artery. The Interventional Radiology (IR) team would only be able to perform angioembolization via contralateral access where the REBOA Catheter was in place. Prior to removing the REBOA Catheter on the right, left CFA access was obtained in the event a new catheter needed to be deployed. Ultimately, IR performed angioembolization without a second REBOA Catheter. In gaining contralateral access prior to removing the REBOA Catheter, this case provides a strategy for expeditious replacement of REBOA Catheters in situations where the catheter interferes with hemorrhage control procedures.
More Related Videos
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management