Influence of inner ear impedance on middle ear sound transfer functions
Sijia Zhai1, Matthias Bornitz1, Till Moritz Eßinger1
1Technische Universität Dresden, Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology Head and Neck Surgery, Ear Research Center Dresden (ERCD), Fetscherstraße 74, 01307, Dresden, Germany.
Introduction:
For experimental studies on sound transfer in the middle ear, it may be advantageous to perform the measurements without the inner ear. In this case, it is important to know the influence of inner ear impedance on the middle ear transfer function (METF). Previous studies provide contradictory results in this regard. With the current study, we investigate the influence of inner ear impedance in more detail and find possible reasons for deviations in the previous studies.
Methods:
11 fresh frozen temporal bones were prepared in our study. The factors related to inner ear impedance, including round window membrane stiffness, cochleostomy, cochlea fluid and cochlea destruction were involved in the experimental design. After measuring in the intact specimen as a reference (step 1), the round window membrane was punctured (step 2), then completely removed (step 3). The cochleostomy was performed (step 4) before the cochlear fluid was carefully suctioned through scala tympani (step 5) and scala vestibuli (step 6). Finally, cochlea was destroyed by drilling (step 7). Translational and rotational movement of the stapes footplate were measured and calculated at each step. The results of the steps were compared to quantify the effect of inner ear impedance changing related to the process of cochlear drainage.
Results:
As the inner ear impedance decreases from step 1 to 7, the amplitudes of the METF curves at each frequency gradually increase in general. From step 6 on, the measured METF are significantly different with respect to the intact group at high frequencies above 3 kHz. The differences are frequency dependent. However, the significant decrement of rotational motion appears at the frequencies above 4.5 kHz from the step 5.
Conclusion:
This study confirms the influence of inner ear impedance on METF only at higher frequencies (≥3 kHz). The rotational motions are more sensitive to the drainage of fluid at the higher frequency. Study results that found no influence of cochlea impedance may be due to incomplete drainage of the cochlea.
Related Concept Videos
Anatomy of the Ear
The Cochlea
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
The Auditory Ossicles
The aptly named stapes look very much like a stirrup. The three ossicles are unique to mammals, and each plays a role in...
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same...
Network Function of a Circuit