Related Experiment Video
Updated: Jun 29, 2025

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Optical Coherence Tomography-Based Functional Stenosis Assessment: FUSION-A Prospective Multicenter Trial
Allen Jeremias1,2, Akiko Maehara2,3, Mitsuaki Matsumura2
1St. Francis Hospital & Heart Center, Roslyn, NY (A.J., R.A.S., Z.A.A.).
Background:
Intravascular imaging and intracoronary physiology may both be used to guide and optimize percutaneous coronary intervention; however, they are rarely used together. The virtual flow reserve (VFR) is an optical coherence tomography (OCT)-based model of fractional flow reserve (FFR) facilitating the assessment of the physiological significance of coronary lesions. We aimed to validate the VFR assessment of intermediate coronary artery stenoses.
Methods:
FUSION (Validation of OCT-Based Functional Diagnosis of Coronary Stenosis) was a multicenter, prospective, observational study comparing OCT-derived VFR to invasive FFR. VFR was mathematically derived from a lumped parameter flow model based on 3-dimensional lumen morphology. Patients undergoing coronary angiography with intermediate angiographic stenosis (40%-90%) requiring physiological assessment were enrolled. Investigational sites were blinded to the VFR analysis, and all OCT and FFR data were reviewed by an independent core laboratory. The coprimary end points were the sensitivity and specificity of VFR against FFR as the reference standard, each of which was tested against prespecified performance goals.
Results:
After core laboratory review, 266 vessels in 224 patients from 25 US centers were included in the analysis. The mean angiographic diameter stenosis was 65.5%±14.9%, and the mean FFR was 0.83±0.11. Overall accuracy, sensitivity, and specificity of VFR versus FFR using a binary cutoff point of 0.80 were 82.0%, 80.4%, and 82.9%, respectively. The 97.5% lower confidence bound met the prespecified performance goal for sensitivity (71.6% versus 70%; P=0.01) and specificity (76.6% versus 75%; P=0.01). The area under the curve was 0.88 (95% CI, 0.84-0.92; P<0.0001).
Conclusions:
OCT-derived VFR demonstrates high sensitivity and specificity for predicting invasive FFR. Integrating high-resolution intravascular imaging with imaging-derived physiology may provide synergistic benefits as an adjunct to percutaneous coronary intervention.
Registration:
URL: https://clinicaltrials.gov; Unique identifier: NCT04356027.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

