Related Experiment Video
Updated: Aug 13, 2026

In situ Transverse Rectus Abdominis Myocutaneous Flap: A Rat Model of Myocutaneous Ischemia Reperfusion Injury
Published on: June 8, 2013
Application of Platysma Myocutaneous Flap in Surgical Repair after T2-3 Glottic Carcinoma Resection
Wenying Zhu1, Haifeng Liang1, Faya Liang1
1Department of Otolaryngology-Head and Neck, Sun Yat-sen Memorial Hospital, Sun Yat-sen University.
Objective:
Numerous methods and materials are available for vertical partial laryngectomy. In this study, the reparative effects of the platysma myocutaneous flap (PMF) and ribbon myocutaneous flap (RMF) on the postoperative voice quality of patients were compared to provide a reference for selecting a method conducive to improving postoperative voice quality.
Methods:
A retrospective analysis was performed on patients with unilateral T2-3 glottic carcinoma. Following vertical partial laryngectomy, the defect was repaired with a PMF or simple RMF. Twelve months after surgery, voice quality was assessed according to voice acoustics, aerodynamics, and subjective perceptual evaluation, and glottic morphology was recorded using a laryngeal stroboscopy.
Results:
A total of 70 patients were identified, including 54 in the PMF group and 16 in the RMF group. The PMF group was superior to the RMF group in terms of voice quality assessed by voice acoustics, aerodynamics, and subjective perceptual evaluation. In the PMF group, 72.2% of patients performed phonation with their vocal cords, and approximately 27.8% of patients were affected by supraglottic compression. In the RMF group, 81.3% of patients were affected by supraglottic compression. No significant difference was found in the 5-year survival rate between the two groups.
Conclusion:
For defect repair following vertical partial laryngectomy, a PMF can allow better postoperative voice quality to be achieved than an RMF because a PMF can provide more tissue (including strap muscle under the flap) for padding, which enables the glottic portion corresponding to the vocal cord to close well.
Level Of Evidence:
3 Laryngoscope, 134:3181-3186, 2024.
Related Concept Videos
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Pneumothorax-II
Clinical Manifestations:
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...

