Setup time analysis for stereotactic body radiotherapy in O-ring linear accelerator without rotational correction.
Biplab Sarkar1,2, Anirudh Pradhan3
1Department of Radiation Oncology, Apollo Multispeciality Hospitals, Kolkata, India. biplabphy@gmail.com.
Radiological Physics and Technology
|March 25, 2024
Summary
This study analyzed setup time (ST) for stereotactic body radiotherapy (SBRT) without automatic rotational correction. Mean setup times varied by site, with challenges in managing unknown rotational errors.
Area of Science:
- Radiation Oncology
- Medical Physics
Background:
- Stereotactic body radiotherapy (SBRT) requires precise patient positioning.
- The absence of automatic rotational correction presents challenges in setup accuracy.
Purpose of the Study:
- To analyze setup time (ST) and on-board imaging frequency in SBRT for abdomen, lung, and spine.
- To evaluate the impact of rotational errors on SBRT setup without automatic correction.
Main Methods:
- Retrospective analysis of 53 SBRT patients (28 abdomen, 19 lung, 6 spine) treated over 230 sessions.
- Evaluation of setup time and Cone-Beam CT (CBCT) frequency using an O-ring gantry accelerator.
Main Results:
- Mean ST: 7.7±7.4 min overall; 9.2±9.2 min (abdomen), 6.3±4.1 min (lung), 5.5±3.3 min (spine).
- Median CBCT use was 2 per patient; 96% received 1-3 CBCTs.
- Setup times predominantly fell within 0-20 minutes (95.7%).
Conclusions:
- Managing rotational errors is a key challenge in SBRT without automatic correction.
- Accurate knowledge of rotational errors can facilitate treatment delivery.
- Setup times are generally manageable, but rotational errors require careful consideration.
Related Concept Videos
Rotation with Constant Angular Acceleration - I
If angular acceleration is constant, then we can simplify equations of rotational kinematics, similar to the equations of linear kinematics. This simplified set of equations can be used to describe many applications in physics and engineering where the angular acceleration of a system is constant.
Using our intuition, we can begin to see how rotational quantities such as angular displacement, angular velocity, angular acceleration, and time are related to one another. For example, if a flywheel...
Using our intuition, we can begin to see how rotational quantities such as angular displacement, angular velocity, angular acceleration, and time are related to one another. For example, if a flywheel...
Positron Emission Tomography
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Relative Motion Analysis using Rotating Axes - Acceleration
Consider a component AB undergoing a linear motion. Along with a linear motion, point B also rotates around point A. To comprehend this complex movement, position vectors for both points A and B are established using a stationary reference frame. The absolute velocity of point B is determined by adding the absolute velocity of point A, the relative velocity of point B in the rotating frame, and the effects caused by the angular velocity within the rotating frame.
Time differentiation is...
Time differentiation is...