Comparison of Refractive Prediction Error by Axial Length in Flanged Intrascleral Intraocular Lens Fixation
Yoshiaki Kabata1, Tetsutaro Oki1, Tadashi Nakano2
1Department of Ophthalmology, Jikei University School of Medicine, Daisan Hospital, Tokyo, Japan.
Purpose:
To evaluate the refractive prediction error in flanged intrascleral intraocular lens (IOL) fixation using the SRK/T formula and compare the axial length using a single IOL.
Methods:
Seventy-six eyes from 70 patients (45 males and 25 females) were included in this study. The mean age at the time of surgery was 73.4 ±12.3 years. The patients underwent flanged IOL fixation using a PN6A (Kowa). All surgeries were performed by two surgeons (Y. K. and T. O.) between Jan 2020 and Dec 2022 at Jikei University Daisan Hospital. IOL power was calculated using the SRK/T formula with IOL Master 700 (Carl Zeiss) as the bag power. The recommended value of 119.0 was used for the A-constant. The actual refractive spherical equivalent was calculated and compared with preoperative predictions. Refractive prediction errors were defined as the deviation of the actual postoperative spherical equivalent refraction in diopters from the predicted preoperative spherical equivalent refraction. The patients were divided into three groups according to axial length: <22.0 mm (short eyes), 22.0-24.5 mm (medium eyes), and >24.5 mm (long eyes), and the refractive prediction errors and mean absolute errors were compared.
Results:
The mean refractive prediction error was -0.20 ± 0.52D. The mean absolute error was 0.44 ± 0.33D. The mean refractive prediction errors were not significantly different between the 22.0-24.5 mm (medium eyes) and >24.5 mm (long eyes) groups. (P=0.06) The mean absolute errors were not significantly different between the two groups (P=0.10).
Conclusion:
The SRK/T formula worked well regardless of whether the eyes were medium or long according to the axial length in the flanged intrascleral IOL fixation.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment